Aerovex Systems Introduces New Healthy Air™ “Slim” Nails Source Capture System

A newly designed Healthy Air™ nail source capture system has been introduced by Aerovex Systems, incorporating both a 25% reduction in size, and optional LED lighting now available in the capture hood. The new “Slim” model features whisper quiet operation combined with powerful suction. All, in a slimmed down 12″x14″x20″ size.

In addition, new features include state-of-the-art electronics and an enhanced electronic control panel. Optional venting to the outside is also available to meet the new International Mechanical Building Code, Dec.2012, requiring a source capture system at each nail station.

The new Healthy Air™ Slim unit can be seen here

new nail unit with led usable

Aerovex Systems Chemical Source Capture System feat. Healthy Air Tech™ in the July Issue of Modern Salon

The importance of a healthy salon environment cannot be overstated. It is not only important for the safety and comfort of your stylists, but for your clients as well. Day in and day out, today’s stylists are working in a salon environment that exposes them to airborne chemicals which can cause “sensory irritation” issues and adversely affect their health, if proper salon ventilation is not provided.  By removing harmful chemicals from the breathing zone, the Chemical Source Capture System prevents inhalation of vapors & fumes that occur during keratin smoothing services, color, permanent wave and other chemical hair treatments.

Healthy Air™ Source Capture Systems with eHEPA™ technology – only available from Aerovex Systems,  http://www.healthyair.net/Pages/EHepaVsHepa.aspx

 

mod salon july article

Healthy Air™ Source Capture Systems for Keratin Smoothing and Nail Salons are Easy To Use!

All Healthy Air™ Source Capture systems are easy to assemble, use and maintain!  Below are videos for both our  Healthy Air™ Chemical Source Capture System for Brazilian blowouts and  Healthy Air™ Nails Source Capture System for removal of nail dust and chemical vapors.

Healthy Air™ source capture ventilation is the key to taking salon air pollution out of the breathing zone of your staff and removing it using patented eHEPA™  and advanced activated carbon technology.

See for yourself how  Healthy Air™ from Aerovex Systems  not only beats the competition when it comes to advanced features and performance, but ease of use and maintenance as well 🙂

 

 

 

 

Healthy Air™ Source Capture Systems for Nail Salons Offer State of the Art Filtration

Aerovex Systems’ Nails Source Capture System with new Healthy Air ™ Technology is the next generation in nail salon ventilation technology. Our new portable air ventilation system is built to protect the breathing zones of nail technicians and prevent overexposure to monomer, acetone, and associated acrylic vapors and dusts.

Joining forces with Healthy Air™ technologies, we have created the most powerful and advanced Nails Source Capture System designed for salon chemical fume extraction.

The new Nails Source Capture System with Healthy Air™ technology is uniquely designed, combining eHEPA technology with advanced activated carbon filtration.

Recommended for removing all nails services chemical vapors, odors & dust: Including—but not limited to—ethyl methacrylate (EMA), titanium dioxide, benzoyl peroxide, methacrylic acid, polymethyl methacrylate (PMMA), acetone, gel & acrylic nail dust.

Healthy Air ™ combines an advanced eHEPA technology with advanced activated carbon filtration to capture submicron airborne nail dust particles as well as microorganisms such as bacteria, viruses, mold and fungi, with efficiencies exceeding standard HEPA grade filters.

Healthy Air™ technology also utilizes an advanced activated carbon filter in combination with an energy field to provide sufficient dwell time to effectively adsorb / decompose salon chemical vapors and odor.

Features Include:

  • Available with One or Two Exhaust arms for user with multiple tables
  • eHEPA Filter For Removing the Finest Nail Dust Particles – Advanced Chemical Adsorption & Catalytic Oxidation
  • 3 Speed High Flow Fan
  • Electronic Control Panel with Remote Wireless Controls
  • Easy & Convenient Filter Access
  • Pre-filter for Dust Particles
  • Activated Carbon Filter to aid hazardous chemical removal
  • Optional rectangle extraction hood to lay flat on table
  • Notification for filter change
  • Portable with wheels for easy relocation
  • Exceeds OSHA requirements
  • Available in Black or White
  • Quiet Operation Noise (dB) at 6 ft. (Setting: High/56 Medium/52 Low/51)

Why Choose Aerovex?

For over 25 years Aerovex Systems has been dedicated to making the air you breathe better.  As a founding member of the Professional Keratin Smoothing Council, Aerovex Systems has been a leader in promoting proper ventilation in both hair and nail salon environments, focusing on proper keratin hair smoothing ventilation and source capture ventilation for nail salon dust and odor.

Most recently Aerovex Systems has teamed up with Healthy Air, Inc. in developing state of the art source capture systems for both keratin treatments and nail salon applications.

So why choose Aerovex?  The answer is simple…

Healthy Air Chemical Source Capture System – The Most Advanced System for Keratin Treatment Ventilation

Aerovex Systems Chemical Source Capture System with new Healthy Air™ technology is designed specifically to remove formaldehyde vapors from the breathing zone of hair stylist’s performing keratin hair smoothing services.

We have consulted with hundreds of professional cosmetologists and incorporated their input into our new Chemical Source Capture System.  Highly effective, affordable, extremely user friendly, and yes, quiet!  The next generation of salon ventilation has arrived!

Joining forces with Healthy Air™ technologies, we have created the most powerful and advanced Chemical Source Capture System designed for salon chemical fume extraction.  Healthy Air™ technology eliminates formaldehyde and chemical vapors in keratin hair smoothing treatments and other hair chemical services.                                            

The new Chemical Source Capture System with Healthy Air™ technology is uniquely designed to combine eHEPA technology with advanced activated carbon filtration.

Healthy Air™ utilizes an advanced eHEPA technology to capture submicron airborne particles as well as microorganisms such as bacteria, viruses, mold and fungi, with efficiencies exceeding standard HEPA grade filters.

Healthy Air™ also utilizes an advanced activated carbon filter in combination with an energy field to provide sufficient dwell time to effectively adsorb / decompose salon chemical vapors and odors.

Say goodbye to watery eyes, itchy throat and all the other sensory irritations that come with performing Brazilian keratin treatments!

For more information on this cutting edge salon technology go to  aerovexsystems.com or call 1-800-288-2023 today!

 

 

 

Source Capture Ventilation Key to Proper Keratin Straightening Treatments

 

 


Dependable keratin hair-smoothing/straightening companies will state “use proper salon ventilation during the entire hair smoothing service” in their manufacturer’s instructions and training manuals.  Many salon owners are unaware that to fully protect the stylist, client & salon environment, they need a “chemical source capture system” to provide proper ventilation.

I’ve asked numerous salon owners and stylists what type of ventilation they provide for their keratin hair straightening services, and they usually report using fans & opening windows/doors.  Some report only doing these services at night so their other clients aren’t subject to the fumes/vapors. New ventilation technologies and systems have been developed specifically for salons that offer keratin hair smoothing/straightening services. These systems will help salon owners to comply with current and potentially more restrictive OSHA requirements.  

A salon “chemical source capture system” protects the stylist and client’s breathing zone. An effective salon air purifier will cleanse the air in the stylist’s workstation area & circulate fresh air throughout the salon. Special filters are available which are designed to remove salon vapors/odors & dusts from the buildings’ HVAC system. The bonus is that salons using these innovative salon ventilation control measures and systems will also benefit from the reduction of vapors/odors & dusts created from providing a range of chemical services, including color, bleach, artificial nail services and hair removal.

Patented Healthy Air Technology Now Available in Aerovex Systems’ Chemical Source Capture Systems

Healthy Air TM technology protects the hair stylist’s & their client’s breathing zone by removing formaldehyde fumes and chemical vapors, odors and dusts produced during keratin hair smoothing treatments, at their source.

Dr. Karim Zahedi and a team of scientists at Massachusetts Institute of Technology (MIT) in Cambridge, MA, developed the fundamental technology incorporated into the Healthy Air TM system.

Aerovex Systems and Healthy Air Inc. have worked together to design the completely new Healthy Air TM source capture system based on an enhanced HEPA technology, referred to as eHEPA.  The high energy field raises the capture efficiency and adsorption of keratin smoothing formaldehyde fumes and other salon chemical vapors and odors. This process also captures and decomposes airborne germs and viruses, while extending the useful life of the filter to four times longer than a HEPA filter.

eHepa and activated carbon filtration in combination with an energy field, holds pathogens, chemical vapors and odors in the filter longer so they can be adsorbed and decomposed. The end result is a system that removes the dangerous fumes from the breathing zone and then effectively captures them on filtration media, providing a cleaner and healthier air for salons.

This technology is exclusive to Aerovex Systems and not available in other source capture ventilation systems.

Now for the first time salons can remove germs and pathogens from your breathing zone and salon air along with chemical vapors and dusts produced during any hair salon chemical service.

 

The Chemical Source Capture System with Healthy Air Technology features a clear hood and easy to change plug and play filter system

Key features of the “Healthy Air” Chemical Source Capture System include:

·  Protects stylist’s & client’s “breathing zone”

·  Cleans the air from chemicals and particles

·  New eHEPA™ technology combines the use of a high energy field with   traditional HEPA filtration process

·  Enhanced activated carbon filtration

·  Electronic control panel with remote control

·  Newly designed clear hood with LED lighting

·  Sturdier, solid ergonomic design

·  Quiet: approx. 58 dBa at 6 feet

·  Notification for filter change

·  Portable with wheels for easy relocation

·  Exceeds OSHA requirements

For more information on how to protect you and your clients breathing zones  call 1.800.288.2023 or go to www.aerovexsystems.com

 

 

 

Doug Schoon Presents the Top Ten Myths Related to Artificial Nails

Myths.  They are all around us.  Whether it be urban legend or something that is related to our everyday life, it is important to dispel fiction from facts.  This is especially important when it comes to things that you deal with everyday life and affect you directly, like your profession.

Doug Schoon, scientist and internationally known expert on the nail salon industry has laid out 10 popular myths related to artificial nails that will help modern nail technicians separate fact from fiction.  Highlighted in this post is myth number 9 on Mr. Schoon’s list, “You should wear a mask when you do nails”.

Click Here To Read Doug's Article

When proper measures are taken, such as using a source capture ventilation system in your salon, nail dust masks are not necessary.  By using these systems you capture the dust and vapor at the source of the problem, not allowing them to migrate into the salon air.  Masks might work well for stopping dust, but have no effect on stopping harmful vapors from entering your body.  Source capture systems take in this harmful vapor where the work is being done and capture them in a thick bed of activated carbon.

Check out this myth and others here as stated by Mr. Schoon here.

 

 

Doug Schoon Explains How Source Capture Ventilation Allows a Safe Working Salon Environment

 

 “Source capture ventilation” (SCV) is designed to capture salon chemical vapors and dusts at or near its source, protecting the technicians’ or stylists’ “Breathing Zone”,  (which is an invisible two foot sphere in front of you and your client’s mouth from which we draw every breath). SCV also prevents dispersing of contaminants into the salon air.

When properly maintained and the carbon filters are changed regularly, SCV systems are a great way to help ensure salon air quality remains safe and everyone is breathing comfortably during working hours. Both dusts and vapors must be properly controlled. SVC systems do both, which is why I fully support their use in salons.

Nail techs who overexpose themselves to strong odors for long periods can develop a condition called “olfactory fatigue”, which means your nose/brain gets tired of smelling the strong odor, so the brain begins to ignore it. Then you can’t smell odors that others can smell easily. Eventually, this can begin to adversely affect your sense of taste, as well.”

“In the US, it is a legal requirement that salons must have proper ventilation because workers must be provided with a safe working environment. The necessary engineering controls to make this happen are required. Utilizing additional ventilation is always a good choice.”

The 2012 International Mechanical Building Code (IMC), states: Nail stations in nail salons must be provided with a source capture system capable of exhausting not less than 50 cubic-feet-per-minute.

“Use of ceiling fans, opening windows and air conditioning, although they do circulate air and will reduce concentrations of salon chemical vapors, mists and dust, are not proper salon ventilation control measures.”

Use of appropriate ventilation is necessary in the salon to control vapors and minimize the potential for “sensory irritation” and adverse health reactions. Salons that are not equipped with the appropriate ventilation needed to prevent sensory irritation should NOT provide these services until the situation is corrected. Proper ventilation that is appropriate for the services being performed is VERY important for both the client and salon professional. The best way to prevent clients’ and stylists’ overexposure to formaldehyde vapors is to use local source capture ventilation. As stated by the Professional Keratin Smoothing Council, www.pksc.org, in its, Oct. 2011 press release:

Aerovex Systems, one of our founding members, is the developer of a hair salon source capture ventilation system, which provides a premiere example of “appropriate” salon ventilation equipment. Such equipment is useful for many types of salon services, including keratin hair smoothing, and can offer an extra layer of protection to help ensure the safety of clients and cosmetologists”.